Feature Highlights

The summary below lists the new features included in this and earlier releases of EnergyPlus (2.2.0, 2.1.0, 2.0.0, previous versions).

New Features in Versions 2.2.0

Data Sets

  • Electronic enthalpy air-side economizer curves
  • Microturbine electric generators

Daylighting

  • Reference point Illuminance levels calculated by DElight now included in standard output variables.
  • DElight reference points now show up on DXF outputs.

Design Day

  • Design days now allow scheduled input for Beam and Diffuse Solar values.
  • Design days allow users to select periods from weather files to be used in design/sizing calculations.

Input

  • Example input files created for all new features (More than 245 example input files now available). An additional set of realistic, benchmark files (15) have been added.

Zone Model

  • Internal gains can now be entered in intensity:
    • People can be entered as number of people, people/floor area or vice versa (area/person).
    • Lighting can be entered as total Watts, Watts/floor area or Watts/person.
    • Equipment (electric, gas, other) can be entered as Watts, Watts/floor area or Watts/person.

Natural and Mechanical Ventilation

  • Outside Air Controller now allows boosted air flow rates for high humidity control. A schedule may also be used to operate the outside air economizer based on a time-of-day schedule. Each of these features is also included in the controller for the stand-alone energy recovery ventilator.
  • Infiltration can be entered as total volume, volume/floor area, volume/exterior surface area, or air changes per hour.
  • Ventilation, mixing and cross mixing can be entered as total volume, volume/floor area, volume/person, or air changes/hour.
  • Airflow network model now includes more coil types, including water cooling, water heating, detailed flat water cooling, multimode DX cooling, and multispeed cooling and heating.
  • Multiple infiltration and ventilation objects now allowed in each zone, and the temperature control limits for the ventilation object can now be scheduled (instead of constant).

HVAC

  • Dual-setpoint humidistat with deadband now available.
  • Water heater volume and capacity can be autosized.
  • New desiccant dehumidifier with additional capabilities and flexibility compared to the existing solid desiccant dehumidifier model.
  • Supply air fan operating mode (continuous versus cycling) can now be scheduled based on time-of-day for window air conditioner, packaged terminal heat pump and water-to-air heat pump.
  • New economizer controls added to Controller:Outside Air and Controller:Stand Alone ERV objects. New controls include Dew Point Temperature limit and Electronic (Variable) Enthalpy limit.
  • DX System (DXSystem:Airloop object) now allows cool-reheat dehumidification control type.

On-Site Energy Supply

  • New operating scheme for electric generators to follow thermal loads.
  • New microturbine electric generator model.
  • Upgraded equivalent one-diode PV model to include options for BIPV and inverter.

Environmental Impacts

  • Environmental emissions can now be scheduled for all fuel types.

Output

  • New detailed reports on Internal Gains (People, Lights, Equipment) as well as Simple Air Flow (Infiltration, Ventilation, Mixing, Cross Mixing) in the .EIO file.
  • New report variables for summed zone load components.
  • Added additional column in internal heat gains reporting that shows the sum of gains/floor area.

Utilities

  • Many enhancements in the IDF Editor and HVAC Diagramming tools.

Documentation and Guides

  • Input/Output Reference and Engineering Reference updated and extended for all new features and updates. Total documentation now exceeds 3700 pages.

New Features in Version 2.1.0

Data Sets

  • Color schemes for DXF (original and default)

Input

  • Example input files created for all new features (More than 225 example input files now available).

Geometry/Window/Wall/Shading

  • Surface Surround Subsurface error detection more robust (less false errors)
  • Autocalculate now allowed for shading surfaces (number of vertices)

Zone Model

  • Zone sizing calculations now include heat gains from domestic/service hot water uses and water heaters.
  • User now can choose between ASHRAE Clear Sky and Zhang-Huang solar radiation models for use in design day calculations.

Natural and Mechanical Ventilation

  • New system availability manager allows system-level control of hybrid ventilation systems.

HVAC

  • Water-cooled condenser option added to refrigeration compressor racks for useful heat recovery.
  • Chilled and hot-water coils can now be used in the outside air system to preheat or precool outside air.
  • New desiccant dehumidifier with additional capabilities and flexibility compared to the existing solid desiccant dehumidifier model.
  • Water side economizer (including simulation of integrated and non-integrated water side economizers).
  • Water heater improved for indirect heating (e.g. with remote boiler) and autosizable design flow rates for plant connections.
  • Packaged terminal air conditioner (PTAC) added to model a fan, DX cooling coil, and a gas, electric, hydronic or steam heating coil serving a single zone.
  • Multispeed heat pump with up to four discrete speeds for both cooling and heating.
  • Heat losses (and gains) from plant piping.
  • New and updated Compact HVAC objects:
    • Compact HVAC chilled water coils now use the COIL:WATER:COOLING model by default, COIL:Water:DetailedFlatCooling can be selected as an option.
    • Compact HVAC unitary system now supports the draw-thru fan placement option, and allows a schedule for the supply fan operating mode (continuous or cycling).
    • New Compact HVAC options for dehumidification and humidification controls for unitary and VAV system types.
    • New primary-secondary loop options for Compact HVAC chilled water loops.
  • Compact HVAC expanded to support specification of outside air as a combination of flow/person, flow/area and flow/zone.
  • Compact HVAC baseboard heat option added for unitary and VAV zones.
  • New Compact HVAC objects for unitary heat pump, unitary VAV, packaged terminal air conditioner, and packaged terminal heat pump.

Output

  • New tabular reports: surface shadowing, shading, lighting, HVAC sizing, system and component sizing, and outside air.
  • New Report:SurfaceColorScheme allow users to select their own colors for building elements in the DXF output.

Utilities

  • WeatherConverter now produces KML output (for Google Earth) of latitude, longitude, elevation, and a few climate statistics for locations in a list processing run.
  • Add comma delimited form of CLM (ESP-r ASCII files) conversion to WeatherConverter.
  • WinEPDraw produces in new default colors.

Documentation and Guides

  • Completely rewritten Getting Started manual provides more hands-on example exercises and other information for getting up to speed on EnergyPlus.
  • Input/Output Reference and Engineering Reference updated and extended for all new features and updates. Total documentation now exceeds 3500 pages.

New Features in Version 2.0.0

Data Sets

  • New materials data set based on ASHRAE 2005 HOF replaces legacy DOE-2 and BLAST data.
  • Updated solar collector data set from the SRCC adds 55 more collectors for a total of 173.
  • Added air change rate to ventilation loads report in StandardReports data set.

Input

  • Objects and name lengths can now be 100 characters. (Previous limit was 60).
  • New weather data for 86 locations added: 69 in Australia, 16 in Canada, and 1 in Iran.
  • Three new unit ventilator input files created: UnitVent5Zone.idf, UnitVent5ZoneAuto.idf, UnitVent5ZoneFixedOANoCoilOpt.idf.
  • Three new thermal storage example input files created: IceStorage-Parallel.idf, IceStorage-Series-ChillerDownstream.idf, IceStorage-Series-ChillerUpstream.idf.
  • Example input files created for all new features (More than 225 example files now available)

Geometry/Window/Walls/Shading

  • Shadowing Calculations object now allows user to specify maximum figures in shadowing overlaps.
  • Phase change materials (PCM) with variable thermal conductivity and a temperature-enthalpy function incorporated in conduction finite difference solution algorithm.
  • Basement program now outputs EnergyPlus IDF for wall and floor surface temperatures.
  • Users can now enter interzone surfaces once and EnergyPlus will automatically create the mirror interzone surface.

Zone Model

  • Zone Sizing modified to allow standards-type calculation of design outside air flow rates; allows min cooling and max heating limits on design supply air flow rates.

Natural and Mechanical Ventilation

  • Zone forced air units added to reporting of mechanical ventilation rate and loads
  • Simple Ventilation object now reports air changes per hour
  • New options in UnitVentilator include no coil option and fixed amount for outside air control strategy.
  • AirflowNetwork model can now use Zone Exhaust Fan, OnOff supply fan and the DX heating coil objects.

HVAC

  • Water-to-air heat pumps now use RegulaFalsi solution technique to improve robustness and to speed up simulation.
  • Applicability schedule added to System Availability Manager:Low Temperature Turn Off (to support thermal storage).
  • Evaporative condenser option added to existing refrigerated case compressor racks including availability schedule and basin heater with controls.
  • Draw-through fan configuration added for furnaces, unitary system and air-to-air heat pumps.
  • Different supply air flow rates now allowed for cooling, heating and when no cooling or heating is required in unitary, furnace and air-to-air heat pumps.
  • Common Pipe for Primary-Secondary systems provides an alternative to the Connection component object to model Primary-Secondary systems
  • Balanced flow desiccant heat exchanger option added for the existing heat exchanger-assisted DX cooling coil object.
  • Stratified water heater model added.
  • Uniform load distribution option added to plant load range based operation scheme.
  • Height-dependent air temperature and wind speed now available for most HVAC systems.

Water Manager

  • Green roof simulation added.

On-Site Energy Supply

  • Fuel cell model updated.
  • Combustion micro cogeneration model added.

Output

  • Report Variables and Meter Variables (rdd and mdd) separately reported and output as IDF.
  • Meters can now report cumulative value in addition to resetting at reporting time interval.

Utilities

  • New EP-Launch utility tab added where users can launch Basement, CalcSoilSurfTemp, CoeffCheck, CoeffConv, Slab and Weather utilities.
  • CSVproc now supported in EP-Launch.
  • IDF Editor now preserves the order of user IDFs and includes a large number of other new features.

Documentation and Guides

  • Input/Output Reference and Engineering Reference updated and extended for all new features and updates. Total documentation now exceeds 3300 pages.